FTU Feeder Terminal


The DAE-F series feeder terminal is an intelligent terminal device installed in distribution rooms or on feeders. It can communicate with remote distribution substations, transmitting operational data from distribution equipment to the substation while also receiving control commands from the substation to manage and adjust distribution equipment. It features remote control, remote signaling, and fault detection capabilities, and communicates with the main station of the distribution automation system to provide real‑time information on the operation of the distribution system and various parameters—including switch status, power parameters, phase‑to‑phase faults, ground faults, and fault‑related parameters—while executing commands issued by the distribution main station to regulate and control distribution equipment. This enables functions such as fault location, fault isolation, and rapid restoration of power to non‑faulted areas.

Product Description


Product Overview

The DAE-F series feeder terminal is an intelligent terminal device installed in distribution rooms or on feeders. It can communicate with remote distribution substations, transmitting operational data from distribution equipment to the substation while also receiving control commands from the substation to manage and adjust distribution equipment. It features remote control, remote signaling, and fault detection capabilities, and communicates with the main distribution automation station to provide real‑time information on the operation of the distribution system and various parameters—including switch status, power quality parameters, interphase faults, ground faults, and post‑fault parameters—while executing commands issued by the distribution main station to regulate and control distribution equipment. This enables functions such as fault location, fault isolation, and rapid restoration of power to non‑faulted areas.

Main Features

1. In communication-enabled mode, it features “remote maintenance” functionality.

2. Flexible configuration: All protection functions can be independently enabled or disabled.

3. The device features comprehensive self‑checking functionality and performs online monitoring of the operational status of each component.

4. The closing circuit features an anti-misoperation design and includes a function to prevent unintended tripping.

5. By selecting different configurations, it can meet the “Three Remotes” and “Two Remotes” requirements of State Grid and Southern Power Grid.

6. Meet the requirements of various regions (such as Shandong, Beijing, Guangdong, etc.).

7. Features adaptive zero-sequence current setting, eliminating the need for manual configuration.

8. Meet the specific requirements for “primary–secondary integration.”

Main Technical Parameters

Electromagnetic Compatibility Characteristics

Insulation resistance 
Dielectric strength 
Voltage Sags and Interruptions 
Common mode 
High‑frequency interference 
String mold 
Transient Pulse Group 
Surge interference 
Electrostatic discharge 
Power-frequency magnetic field 
Damped Oscillation 
Impulse Voltage

≥10 MΩ 
2.5 kV 
100%, 0.5s 
1.5 kVp 
2.5 kVp 
4.0 kV, 1 min 
4.0 kV, 1 min 
8 kV 
100 A/m 
100 A/m 
5 kV, 1.2/50 μs



IEC1000-4-1 
IEC60870-2-2:1996 
IEC60870-2-2:1996 
EC60870-2-2;1996 
IEC60870-2-2;1996 
IEC60870-2-2;1996 
IEC 1000-4-8 
IEC 1000-4-8 
IEC60870-2-2;1996

Power supply

Working power supply 
Power Consumption 
Frequency

AC 220V or 100V 
≤10W 
50Hz or 60Hz

Rated value

Current transformer 
Voltage Transformer 
Frequency

5A, Power Consumption < 1.0 VA/Phase 
220V, power consumption < 0.5 VA per phase 
50Hz or 60Hz

Protection Performance Parameters

Instantaneous protection range 
Overcurrent Protection Range 
Overcurrent Protection Delay 
Number of Reclosing Operations 
Reclosing Interval

(20%~2000%) × In is continuously adjustable with a resolution of 0.01 A. 
(20%~2000%) × In is continuously adjustable with a resolution of 0.01 A. 
Continuously adjustable from 0 to 99.99 seconds, with a resolution of 0.01 A. 
0–3 times: You can freely set the number of overlaps. 
0–999.9 seconds, continuously adjustable with a resolution of 0.1 seconds.

Protection Level

Stainless Steel 304 Outdoor Enclosure

No lower than IP54

Mean Time Between Failures

Mean Time Between Failures

No less than 80,000 hours